Prefabricated Mechanical Room Solutions for Warehouse Owners

You deserve the quality and competency you remember from days ago. Behold, the Blueprint Cage provides you access to industrial grade equipment at direct purchase pricing.

BPH 6C-SNO
SNOW & DHWG
HEATING CAGE

Blueprint 6-Pump Heating & Plumbing Cage

Designed and built to provide snow melting, hydronic air, domestic hot water generation, floor, wall or radiator heating via injection piping strategy. This cage is primarily designed to obtain energy from a boiler. Weather-responsive and safe closed-loop heating system perfect for a new or retrofit mechanical room.

BPH 13C-SNO Snow & RFH Cage

Blueprint 13-Pump Heating & Plumbing Cage

Designed and built to provide four (4) radiant floor heating zones via injection piping strategy, four (4) air handlers units, outdoor snow meeting via heat exchanger and domestic hot water generation via indirect storage vessel. Designed to work with a boiler. Weather-responsive and safe closed-loop heating system perfect for a new or retrofit mechanical room.

BPH 7C Multi-Zone Cage

Blueprint 7-Pump Heating Cage

Seven (7) single temperature zones of hot water space heating radiant floor, wall, ceiling and radiator via straight piping strategy and computer control. This weather-responsive Cage is primarily designed to obtain energy from a boiler and is perfect for a new or retrofit mechanical room. A safe closed-loop heating system. 

BPH 8C-S Solar & DHWG Heating Cage

Blueprint 8-Pump Solar, Radiant, Plumbing & Heating Cage

Five (5) zones of hot water radiant space heating via primary/secondary piping strategy. Solar water as primary source of energy with fossil fuel as back up. Domestic hot water production via indirect-fired storage vessel and spa heating. A safe closed-loop heating system perfect for new construction or retrofit applications. Designed to work with alternative energy sources and a boiler. 

BPH 3C-BLR Multi-Zone Heating Cage

Blueprint 3-Pump Heating Cage w/Boiler

The ultimate convenience in plug-and-play mechanical rooms with built-in low-temperature condensing boiler. Designed and built to provide two (2) zones of radiant hot water heating via injection piping strategy. Weather-responsive and safe closed-loop heating system perfect for a new or retrofit mechanical room. 

BPH 2C Boiler Companion Cage

Blueprint 2-Pump Heating Cage

Two (2) single temperature zones of hot water space heating radiant floor, wall, ceiling and radiator via straight piping strategy and computer control. This weather-responsive Cage is primarily designed to obtain energy from a boiler. A safe closed-loop heating system perfect for a new or retrofit mechanical room. 

BPH F2C HWT Heating Cage

Blueprint 2-Pump Flat Heating Cage

One (1) zone of hot water radiant space heating via heat exchanger for safe closed-loop system. Designed to work with a hot water tank. Perfect for new or retrofit construction applications. 

BPH 3C RFH Heating Cage

Blueprint 3-Pump Heating Cage

Designed and built to provide three (3) radiant zones of hot water heating via straight piping, fixed-temperature strategy. Works with hot water tank or boiler. Perfect for retrofit or new construction. Safe closed-loop heating system. 

BPH 2C-HI-LO Snow & RFH Cage

Blueprint 2-Pump Heating Cage

Designed and built to provide one (1) hi-temp zone of hot water heating for either domestic hot water production or space heat. Plus one (1) low-temp zone of radiant heating via floating motorized mixing valve strategy. Works with boiler. Perfect for retrofit or new construction. Safe closed-loop heating system. 

BPH F2C LWCO HW Heating Cage

Blueprint 2-Pump Flat Heating Cage

Two (2) zones of hot water radiant space heating via straight piping strategy. Perfect for retrofit and new construction applications. Designed to work with a boiler. 

BPH 1C Multi-Zone Cage

Blueprint 1-Pump Heating Cage

One (1) single temperature zone of hot water space heating radiant floor, wall, ceiling and radiator via straight piping strategy. This Cage is primarily designed to obtain energy from a boiler or hot water tank. A safe closed-loop heating system perfect for a new or retrofit mechanical room.

BPH 1 FC Single Zone Flat Cage

Blueprint 1-Pump Flat Heating Cage

One (1) single temperature zone of hot water space heating radiant floor, wall, ceiling and radiator via straight piping strategy. This Cage is primarily designed to obtain energy from a hot water tank. Safe closed-loop heating system perfect for a new or retrofit mechanical room.

BPH 3C-HTG Plumbing Cage

Blueprint 3-Pump Plumbing & Lite Heating Cage

Water conservation with multi-port potable hot water recirculation for instant hot water delivery at plumbing fixtures. Built-in sediment cartridge and carbon block for taste and order. Two (2) zones of lite radiant space heating via heat exchange for safe closed-loop system. Adjustable manual control for fixed-blended, potable hot water temperature out to facility. Includes irrigation and fire protection point of connections plus an adjustable temperature delivery for outside vehicle wash station. Designed to work with a hot water tank. 

BPH 1FC-ADD Single Zone Heating Flat Cage

Blueprint 1-Pump Flat Heating Cage

Designed and built to provide one (1) zone of radiant hot water heating via 3-way fixed mixing valve strategy. Safe closed-loop heating system perfect for add-on to an existing boiler heating system. 

BPH 4FC Retrofit Flat Cage

Blueprint 4-Pump Flat Heating Cage

One (1) low-temperature zone of hot water space heating radiant floor, wall, ceiling and radiator via injection piping strategy and computer control. This weather-responsive Flat Cage can obtain energy from a boiler. Safe closed-loop heating system is perfect for mechanical room retrofit to existing equipment. 

BPH 6C-LT Radiant Heating Cage

Blueprint 6-Pump Low-Temp Heating Cage

Six (6) zones of low-temperature hot water radiant space heating via floating mixing strategy. A safe closed-loop system designed to work with a boiler. Perfect for new or retrofit constructions.

Terms & Conditions

Design fees are subject where necessary and specified. All sales ar efinal. 70% deposit is required to initiate purchase order. Remainder 30% is required just prior to delivery. Proof of completion will be provided by electronic or post office mailing of video and photos of package readiness. 

Delivery will not be established without authorization and completion of funds transfer. 

Upon completion of final payment Blueprint Cages will provide a shipment tracking number. Any form of prior delivery is available for any shipment order upon specific request. Blueprint Cages accepts most forms of electronic and US mail payments. 

Warranties

Blueprint Cages operates as a design/build manufacturer. All “Cage” assembly workmanship is exclusively warrantied for 3 years from date of shipment. All components specified and assembled inside cages are carefully chosen for performance and longevity. Most of the components come with a one-year warranty. Applicable manufactures warranty apply. Goods shall be given normal usage and operation in conformance with Blueprint and applicable manufacture’s requirements. Blueprint is in continuous development of new products. Changes in specification and product can occur without notice.